- Outras empresas da Fluke:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
Veja mais marcas da Fluke
TITLE | VER | USE WITH | DOCUMENTS |
COMPASS® for Pressure™ |
5.0.50 2018.11.01 |
FPG8601, PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCH, PPCK, PPCK+, RPM3, RPM4, 7050, 7052, 7250, 7252, 7350, 7615, 7750, 7010, 7215, 2465, 2456 Third party piston gauges, pressure controllers and T&M hardware. |
Example Setup Database » A COMPASS example greatly simplifies the requirements of adding a new device to the COMPASS. |
Description When downloaded, this file can be run to install COMPASS for Pressure Basic and COMPASS for Pressure Enhanced. |
|||
Summary COMPASS® for Pressure is a universal platform for all of your pressure calibration software needs. From piston gauges calibrating individual devices in the cal lab to transfer standards characterizing racks of sensors in production, COMPASS provides an off-the-shelf software tool to maximize the automation of your calibration and testing processes. COMPASS for Pressure integrates calibration functions with pressure specific dependencies that are missing from more generic software packages. Thanks to COMPASS's flexible data output options, the data it collects is easily imported into higher level applications such as Fluke MET/CAL®. This allows the benefits of COMPASS's specialization in pressure calibration to be enjoyed while maintaining the link to your organization's overall calibration management system. |
Updates Include: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
4.00.22 (2011.08.19) | |
ADD(CP-776) | A new [Tools][Repair Template Macros] option was created in the Report Editor. The menu is available only when editing an existing template. Use the item to map macros in a template to corresponding macros in a new database. The macros must already exist. Please review the Help in the Report Editor for additional details. |
ADD(CP-788) | New COMPASS profile for Ruska 2456-LEM environmental monitor. |
ADD(CP-819) | The PPC4E is now supported via the Auto Detect setup option. |
ADD(CP-837) | The comparison and device output displays now include resize controls. Displayed values can be resized with the slider on the right-hand-side of the form, or via the keyboard, using SHIFT <> (or up and down). The font can be set to bold/normal, by right-clicking on the slider or via CTRL-B |
ADD(CP-854) | Several new example devices were added to the default database. |
ADD(CP-877) | Support Ruska controllers and monitors as auto-detected devices. All 7000 series controllers and models are supported. Note that the System Controllers are excluded and must be setup with direct remote commands. |
ADD(CP-890) | Ruska piston gauge features are now supported in COMPASS. An import from WinPrompt option was added to the [Tools] menu. |
ADD(CP-903) | DHI and Ruska piston gauges include a graphical indicator for piston position and rotation. |
ADD(CP-912) | New COMPASS profile for Ruska 2465-Autofloat. |
ADD(CP-915%) | Added seat-based license scheme that allows user to purchase specified number of seats and to add additional seats into existing COMPASS license |
ADD(CP-958) | All device setups in COMPASS support the selection of a MET/TRACK asset. All non DUT assets are now used as standards for the DUT. |
ADD(CP-974) | Pressure media used by WinPrompt and PressCal are included as default media selections. |
ADD(CP-978) | Intermediate calculation results are now visible within the PG Calculator |
ADD(CP-980) | "Vent Head" correction was added to support resevoir head corrections in a piston gauge. |
ADD(CP-982) | New piston gauge mass loading resolutions of 5mg, 20mg and 50mg were created. |
ADD(CP-994) | COMPASS Export to MET/BASE now supports prompting for additional values to be entered on-the-fly, during the import, for the Inventory and Calibration tables. The feature is driven by and configured via the file compassexport.prm in the C \DHI\COMPASS for Pressure directory. Review the help file for additional details. |
ADD(CP-997) | Added option to support 2nd fluid medium for non-autodetect piston gauges |
ADD(CP-1009) | Various units of measure are now supported for the characteristics that define a piston cylinder, a mass set and a mass bell. |
ADD(CP-1043) | Support "Negative Gauge" mode for non-autodetect piston gauges. |
ADD(CP-1107) | A new Tip of the Day feature was added. Enable and disable the tips by using the [Help] menu in COMPASS. |
ADD(UMC-7) | Custom units created in the Unit of Measure converter are now stored in the database. |
CHG(UMC-11) | Ruska unit of measure conversions are applied win "inH2O" based units are selected. DHI unit of measure conversions are applied with "inWa" based units are used. Refer to the Unit of Measure help to see the difference between the conversions. |
CHG(CP-831) | The flashing edit indicator is now yellow when creating a new record while editing an existing record flashes red. This applies to DUTs, Test Definitions, Support Devices and all editors within COMPASS. |
CHG(CP-815%) | Reference Raw Output #1 is included as a data header by default on new installations of COMPASS. Existing users that upgrade are not affected. |
CHG(CP-962) | Revised COMPASS export to MET/BASE. Supports creation of (up to 7) Standards (links) and has optional prompts. |
CHG(CP-973) | The piston gauge calculator now simultaneously displays both the pressure resolution and the mass loading resolution. Previously it was one value or the other. |
CHG(CP-987) | COMPASS setup database is now encrypted and cannot be directly accessed from MS Access without a password. |
CHG(CP-1012) | The "Constant Offset" field on the Tolerance tab of the Piston-Cylinder Editor was removed. |
CHG(CP-1020) | Use Fluke Calibration in product description and logo |
CHG(CP-1051) | The installation program now present an option to store the database in a non default location. |
CHG(CP-1061) | COMPASS Export to MET/TRACK now uses imp2.exe and reports progress & messages during the export. |
FIX(CP-55X) | Strip charts properly scroll and resize based on the source data. |
FIX(CP-792) | Print report to PDF file created a seperate file for each page. |
FIX(CP-794) | Changing printers in the Report Editor did not take affect unles the Report Editor is restarted. |
FIX(CP-795) | ATM is used as the pressure exercise min point when 0 is defined as the min exercise point in the Test Definition and an automated piston gauge is used as the pressure reference in absolute by ATM mode. |
FIX(CP-806) | A PG7000/PG9000 used as a raw source instrument would always default to Absolute measurement mode during test initialization. The active measurement mode on the front panel of the PG is now used. |
FIX(CP-807) | During test initialization an incorrect DUT or Reference instrument out of range error message could occur during test initialization. The error message now displays only when the device range is less than the test defined range. |
FIX(CP-811) | All AMH masses are loaded whenever a PPC will be used to exercise the system pressure when the PG is the reference. |
FIX(CP-818) | Macro Editor now scans for and reports on duplicate function names upon save. |
FIX(CP-840) | Enhanced error message for COMPASS Export to MET/BASE in regards to inventory recall interval and unit. |
FIX(CP-841) | Selections on the Tools, Options, MET/TRACK tab were not properly retained when edits to other options were made or when COMPASS is opened or closed. |
FIX(CP-851) | Assets added in MET/TRACK within a COMPASS session might not be available for selection until COMPASS is restarted. |
FIX(CP-853) | Support COMPASS data file with comma as decimal separator for exporting to MET/BASE. |
FIX(CP-868) | COMPASS Export to MET/BASE would attempt to calculate cal due date, rather than export the value from COMPASS |
FIX(CP-887) | The Piston Gauge Calculator doesn't support zero psi as a target pressure. |
FIX(CP-933) | "Include mass bell in minimum PG pressure option" was not functioning properly in all cases. |
FIX(CP-971) | The serial number of Hart instruments as read by command 14 was incorrect whenever the last byte of the serial number had a value less than 16. The issue is now resolved. |
FIX(CP-972) | PG Calculator form size shrinked if the mass list was selected before closing the form in the last section. |
FIX(CP-977) | The DUT tolerance was not properly calculated when a test definition is run in a specific unit of measure that was not the same as the DUTs unit of measure. Tests run in %DUTSpan functioned correctly. |
FIX(CP-983) | Cannot display multiple strip charts on readings of third party PG for which "Auto Detect" is not checked. |
FIX(CP-990) | Set point logged for "MIN" point with PG as controller shows random number even though the pressure target sent to PG is correct. |
FIX(CP-1015) | When exporting data to MET/TRACK C215%1 may be populated with an odd combination of semicolons and NULL |
FIX(CP-1016) | Incorrect upper / lower limits shown on v7 cal report for data exported from COMPASS. |
FIX(CP-1019) | COMPASS units are preserved, with the exception of those which have the milli (m), mega (M) or kilo (k) prefix - which is split off. Now also supports kA, mPa and MV. |
FIX(CP-1021) | The Load Settings option in the test initialization would fail when the model included additional model descriptors. For example "PPC4" would work, but "PPC4 A1000/A100" would fail. |
FIX(CP-1038) | Removed obsolete online reference from new macro header |
FIX(CP-1053) | The Process Gas Editor did not properly support the comma as a decimal separator. |
FIX(CP-1058) | A template macro that is no longer available to a report template is listed as "Missing Macro" instead of a blank line in the Template Macro selection dialog. The macro could be part of a different database or it may have been deleted by the user. |
FIX(CP-1060) | The last file path of a Report Template is used as the default file path when opening a Report Template. |
FIX(CP-1101) | A piston gauge platform with a reference vacuum device would fail to initialize in gauge mode if a prior test were run in gauge mode. |
3.00.43 (SP1) (2011.02.11) | |
ADD(CP-802) | Support PG7000 and PG9000 models that respond with FLUKE as the manufacturer. |
CHG(CP-793) | An automated PG7000/PG9000 system with a PPC and AMH will use ATM as the minimum pressure when exercising in a test that is run in Absolute by ATM. |
3.00.42 (SP1) (2010.07.07) | |
ADD(CP-689) | Support alternate units of measure and temperature references for the Piston Cylinder effective area. |
ADD(CP-775) | Added new instruments to the default database. |
CHG(CP-786) | When [Tools][Feature Options Display]<\ Support Temperature\> is disabled, use the DUT temperature device unit of measure to log temperature data. When the feature is enabled, the temperature unit selected during test initialization defines the unit of measure for the DUT temperature device. |
CHG(CP-785) | The Final Output Label of a device is displayed on the manual entry dialog to assist in the entering of manual data. |
CHG(CP-781) | ATM is a supported target for the pressure exercise min or max targets. Click the label next to the field to insert an ATM point. |
CHG(CP-766) | The build information in addition to the Major and Minor revisions is displayed on the Splash screen during program initialization. |
CHG(CP-753) | Font size is limited on device run screens to prevent fonts that are too large or small. |
CHG(CP-708) | [Help][About] dialog uses the new "Fluke- DH Instruments" logo. |
CHG(CP-691) | A device is now considered "in tolerance" if the error is equal to the tolerance. Previously, a device was "out of tolerance" when the error was equal to the tolerance. |
CHG(CP-159) | When a macro changes the SN or ID of a device it should also be changed on the various device displays. |
CHG(CP-155) | Additional COMPASS specific fields are exported to MET/TRACK. See Help file for complete set of fields that are mapped. |
CHG(CP-657) | The number of test cycle points can be changed from a macro. |
CHG(CP-751) | When the Data File Name selection in [Tools][Options][Data File] is set to secondary SN, the device serial number is used when the selection does not apply. |
FIX(CP-784) | Might encounter "Syntax error near '0'" when exporting test data file to MET/TRACK. |
FIX(CP-783) | Status field logged in the data file does not always update with status codes. |
FIX(CP-779) | The measurement mode of a profile DUT is not recalled between tests. |
FIX(CP-778) | Incorrect reference temperature values logged during automated test with an FPG reference. |
FIX(CP-762) | Export to MET/TRACK, data file resolution was not maintained. |
FIX(CP-761) | Export to MET/TRACK, option |
FIX(CP-760) | Removed redundant error messages associated with data files that cannot be exported to MET/TRACK. |
FIX(CP-759) | A macro run at the end of a test cycle can result in duplicate points made available to a test macro. Data file information is now synchronized prior to calling any test event macros at the end of a test cycle to avoid this problem. |
FIX(CP-756) | The COMPASS Ready option in a Test Definition would fail to return Ready if the reference and controller used different units of measure. |
FIX(CP-755) | Output resolution of DHI devices does not always conform to the front panel when the "...Preserve front panel resolution.." option is selected. |
FIX(CP-754) | Interface macros had a maximum limit of 4 calls per second regardless of the device defined poll interval value. |
FIX(CP-752) | The label associated with values that are manually entered during a tests were not always correct. In particular, when the raw output type and the final output type were different. For example, Ohms and Temperature. |
FIX(CP-747) | Target pressure on a PPC could have excessive resolution. The target is now limited to the resolution of the device. |
FIX(CP-744) | Exporting a COMPASS data file to the Test Data Database might fail if no device information is present in the data record. |
FIX(CP-735) | Line pressure and temperature fields display on final test initialization step even when the options are disabled.v FIX(CP-719) An error message would display when creating a user defined device when the Output Relationship was set to "Same". The error indicated that a unit must be selected from a drop down list when in fact the list was empty. |
FIX(CP-709) | Data viewer now shows only relevant columns on the Data grid, with the appropriate column headings. |
FIX(CP-703) | Effective area unit conversion was performed with limited resolution. This impacted the final area determination which resulted in a faulty piston gauge pressure output. |
FIX(CP-695) | BSL linearity calculation was incorrect. |
FIX(CP-693) | If a test point is removed by a macro and the test definition has multiple cycles of line pressure or temperature, the test would loop indefinitely. |
FIX(CP-157) | Shared command macro information was not exported to external databases using the Database Maintenance Tool. |
FIX(CP-659) | The Piston Gauge Platform editor displays "PC/MS" tab 2 times. The second tab should display "Sources" instead. |
FIX(CP-653) | Newly created Mass Bells are not listed in the Piston gauge Editor Mass Bell list. |
FIX(CP-650) | The True Mass label on the Mass Set Editor is missing. The field displays "kg" only. |
FIX(CP-644) | Controller list for line pressure includes 2 "Manual Entry" choices. |