- Outras empresas da Fluke:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
PG7000/PG9000 Ver 3.1.5.255 Embedded Software
TITLE | VER | USE WITH |
PG7000™ PG9000™ |
3.1.5.255 | All PG7000 models with SN 733 or newer. All PG9000 models. |
Instructions: The PG7000/PG9000 firmware versions 3.00 and newer are intended to work with all PG9000 models and PG7000 models with serial numbers 733 or newer. Do not attempt to upgrade an older PG7000 model with this software. This upgrade does not apply to PG7000-AF products. Contact a Fluke Calibration Authorized Service Center for additional information. Download the file. Run Winflash and select the file downloaded as the file to write to the product. Use a standard RS232 cable to connect the PG7000/PG9000 COM1 port to an available port on the host PC. The updating of embedded software should only be performed after given specific instructions to do so from a Fluke Calibration Authorized Service Center. If the update isn't performed properly, your product will be inoperable until it is. NOTE: The updating of embedded software should only be performed after given specific instructions to do so from a Fluke Calibration Authorized Service Center. Firmware should not be downgraded (rolled back) from v3.1.5.255 or later to versions before v3.1.5.255 unless necessary. Downgrading PG firmware from v3.1.5.255 or later to v3.1.4.308 or lower requires first downgrading to v3.1.3.21 Contact Fluke Calibration Pressure Technical Support at Technical Support |
Updates Include: | |
Ver 3.1.5.255 (2018 Nov 5) ADD (PG-771): Auto-float support for 8270A and 8370A pressure controllers. FIX (PG-801): Auto-float sub-ATM use with 6270A, 8270A or 8370A when multiple PMM modules are required for operation. FIX (PG-804): Unselected active piston may result in memory error and reset. FIX (PG-800): Auto-float using a PPCH and an intensifier will halt at the PPCH upper limit setting Ver 3.1.4.308 (2016 Jun 16) FIX (PG-794): Head height unit text corrupted in SPECIAL/Head/ATM menu. FIX (PG-765): HLD mode does not work. FIX (PG-507): Error when there is a DUT head entered in a PG7000 when used in Differential mode. FIX (PG-763): Autofloat using a PPCH-G can hang or overpressure. Ver 3.1.3.21 (2014 Jan 15) FIX (PG-503): Boolean type remote command arguments are intolerant of trailing white spaces. FIX (PG-502): MEDIA= command argument assumes a user media when the argument does not match any of the standard media types. FIX (PG-501): Received GPIB terminators are converted into whitespaces instead of deleted, causing issues with Boolean argument types and the MEDIA command. FIX (PG-498): Auto Rotate motor turning on/off while on springs with PPCH-G controller. FIX (PG-493): PRTPC command cannot take 10 digit cal report number. FIX (PG-489): "LE50" indicated on PG7601 display. Ver 3.1.2.12 (2011 Aug 18) Ver 3.1.1.14 (2011 Jan 17) Ver 3.01 (2010 Aug 18) Ver 3.00b (2010 April 05) Ver 3.00a (2009 Oct 16) Ver 3.00 (2009 Aug 13) |
- Início
- Produtos
- Novos Produtos
- Calibração elétrica
- Calibração de RF
- Equipamento de aquisição de dados e de teste
- Calibração de temperatura
- Calibração de umidade
- Calibração de pressão
- Medidores de pistão
- Controlador/Calibradores
- Monitores de pressão
- Balanças de peso morto
- Calibradores manuais e monitores
- Handheld Pressure Calibrators
- Calibração de dados de aéreos
- Monitores ambientais
- Acessórios de calibração de pressão
- Sistemas personalizados de calibração de pressão
- Software de calibração de pressão
- Calibração de fluxo
- Ferramentas de Calibração de processo
- Software de calibração
- Serviço e suporte
- Todos os instrumentos de calibração
- Onde Comprar
- Notícias
- Treinamento e eventos
- Literatura e educação
- Serviço e Suporte
- Service Request (RMA)
- Planos de Serviço
- Suporte técnico
- Base de Conhecimento
- Acreditações
- Centros de assistência autorizados
- Calibration Certificates
- Community Forum
- My MET/SUPPORT
- Manuais de produto (Guias de usuário)
- Folhas de Dados de Segurança (SDS)
- Safety, Service, and Product Notices
- Downloads de software
- Sobre Nós